Outdated VERSION. Follow the link for the current version https://www.hexagonmi.com/MSC-Apex-Generative-Design/help
Fixed Bugs & Known Limitations
Fixed Bugs:
The material coordinate system is without function. The global coordinate system acts always as the material coordinate system. The global x-axis is always the build direction. As a workaround the part can be aligned using the Transform Tool.
Known Limitations:
When using Symmetry, the translational displacements may be plotted incorrectly on the result geometry. They might be plotted according to the symmetry coordinate system and not according to the global coordinate system. However, the displacements are considered correctly during the calculation and design generation - just the visualization in the post processing is impacted.
Remote submittal of simulation for Linux is not supported in MSC Apex Generative Design release 2021.2. However, one could use command line submittal of Optimization jobs on both Linux and Windows and import the results into the application. For more information on Command Line Optimization; please see: Generative Design - Command Line Optimisation
MSC Apex Generative Design might not visualize Non-Design Spaces using the Shape Quality “Preview”. The Non-Design Spaces are considered in the optimisation but because of the coarse resolution level of these iterations not visualized (fully). Choose another Shape Quality setting to run a complete optimisation and receive a full visualization.
"Restart" is not directly selectable in the User Interface but is available for the optimisation as an unsupported option using the Advanced User Settings. For more information have a look here.
The simulation may fail using a remote solver due to the case sensitivity of the machine name.
You might not be able to zoom in the stress chart view in Post.
MSC Apex Generative Design may not start up due to the presence of wide-characters in the program path. Please change the location of the program to a path without any wide characters.
While uninstalling MSC Apex Generative Design some files might not be removed.
Machining allowances selected with the GD Configuration Tool might not be the same geometries as before. As a workaround the machining allowances can be created manually on the newly created Design Space.
If Retained Volumes are included, the mass is estimated based on the different densities of the volumes.
When using the GD Configuration Tool, loads and boundary conditions placed on the original parts Non-Design cells will not be transferred to the created Design Space. Please create the loads and boundary conditions after creating the Design Space with the GD Configuration Tool.
An optimisation which uses only 1 CPU Thread cannot be executed. Please adjust the number of CPU Threads in the Application Settings - Generative Design Solver or in case of a Command Line Optimisation in the Configuration File.
When the interface thickness ≥ offset distance then the interface volume will be hidden in GUI due to a current limitation. The optimization will still consider the entered values and the Print Geometry will consider the entered Machining Allowance value.
Copyright (C) 2021, MSC Software Corporation and its licensors. All rights reserved.