In this section you find information about occurring warnings and errors. As we are still gathering information on how/when warnings and errors occur and under which circumstances this site will constantly be updated with new information.
You can find Warning & Error codes displayed in the Studies tab by double clicking on the Generative Design Status or in the log files in the result folder in your workspace (log_error.log & log_warning.log).
Please contact the MSC Apex Support (mscapex.support@mscsoftware.com) if a warning or error occurs which is not yet listed here or cannot be averted by applying the compiled help.
Information regarding the “Analysis Readiness” checks can be found here.
Wf9ae851b
“Probable reduction of the model is more than …% of the starting model.”
This is just a notification that the predicted reduction of the model is very high.
Further information here.
Wf9b42fd9
“Probable reduction of the model is more than …% of the starting model.”
This is just a notification that the predicted reduction of the model is very high.
Further information here.
Wf06bfce1
A material name was not set.
If you are using the Command Line execution execution, please make sure a name for the material is set in the Configuration File file.
Please contact MSC Apex Support.
W86a76001
The Start Space volume is magnitudes smaller than the Design Space.
Check the unit system of your Start Space. When using a Start Space the STL-file needs to be available in the same unit system as the optimisation was setup. Further information about a Restart here.
W1c05e9e6
Result data couldn't be projected onto the result geometry for certain polygons (grey). The stresses and displacements cannot be viewed in certain areas.
W1c075d08
Result data couldn't be projected onto the result geometry for certain polygons (grey). The stresses and displacements cannot be viewed in certain areas.
W1c7b96c7
Result data couldn't be projected onto the result geometry for certain polygons (grey). The stresses and displacements cannot be viewed in certain areas.
W1c0aad3a
Result data couldn't be projected onto the result geometry for certain polygons (grey). The stresses and displacements cannot be viewed in certain areas.
W1c102ca3
Result data couldn't be projected onto the result geometry for certain polygons (grey). The stresses and displacements cannot be viewed in certain areas.
W1cc18b49
No Solver IP was found in the configuration file.
The set up for GPU and/or Remote Solving is not complete. The optimisation will fall back to local CPU solving and continue running. The solver settings can be changed in the Application Settings - Generative Design Solver.
If you are running a Command Line optimisation, make sure the appropriate Solver IP is included in the Configuration File.
If further issues occur, please contact MSC Apex Support.
W1ca9b0d5
No Solver IP was found in the configuration file.
The set up for GPU and/or Remote Solving is not complete. The optimisation will fall back to local CPU solving and continue running. The solver settings can be changed in the Application Settings - Generative Design Solver.
If you are running a Command Line optimisation, make sure the appropriate Solver IP is included in the Configuration File.
If further issues occur, please contact MSC Apex Support.
W1cc213b7
No Solver Port setting was found in the configuration file.
The set up for GPU and/or Remote Solving is not complete. The optimisation will fall back to local CPU solving and continue running. The solver settings can be changed in the Application Settings - Generative Design Solver.
If you are running a Command Line optimisation, make sure the appropriate Solver IP is included in the Configuration File.
If further problems occur, please contact MSC Apex Support.
W1caa0e09
No Solver Port setting was found in the configuration file.
The set up for GPU and/or Remote Solving is not complete. The optimisation will fall back to local CPU solving and continue running. The solver settings can be changed in the Application Settings - Generative Design Solver.
If you are running a Command Line optimisation, make sure the appropriate Solver IP is included in the Configuration File.
If further problems occur, please contact MSC Apex Support.
W1cab408b
The software versions of the Engine and the CUDA Solver do not fit together.
The connection to the external solver was not possible. The optimisation will continue and fall back to local CPU solving.
Please contact MSC Apex Support.
We97dfe00
GPU solution was requested but is not installed - running on the CPU only.
The GPU service is not installed. The optimisation will continue and fall back to local CPU solving.
W39fed060
The Matrix is too large for the GPU solver.
The GPU memory is too small for the model. The optimisation falls back to CPU calculation. Continue calculating on CPU or reduce the matrix by adjusting the model ( e.g. reduce the
Complexity).
W7004d2f0
Inexact match for space/mask …'s file name - this feature is deprecated and will be removed in future releases.
If you are using the Command Line execution, please make sure the full file name including the extension is written correctly into the Configuration File. The optimisation will continue but might not run in future releases.
If you have used the GUI to setup the model, this will be handled automatically.
W7aa7a778
The Machining Allowance … is too small to be represented. Choose a bigger Machining Allowance so that a representation is possible.
W74bbc128
The Machining Allowance is much larger than Design Space. Please check the unit dimensions in Configuration File.
W2ab3f0d8
The Machining Allowance protrudes the build area box. Choose a smaller Machining Allowance.
W61379840
Meshfix warning …
Internal error.
Please contact MSC Apex Generative Design support.
W8637fb82
Cannot check out GPU features.
To use GPU Solving an additional license is necessary. Please check your licenses in Options → License Manager or deactivate GPU solving in the Options → Application Settings - Generative Design Solver. The optimisation will fall back to local CPU solving and continue running.
Wbd1ee66a
Solving on GPU solver failed for a non-fatal reason (solving on CPU can continue):
Either due to W39fed060, W1cc18b49, W1cc213b7, W1cc2b4cd or W8637fb8 or as a result of a GPU solver failure / communication issue.
If any of the other warning codes were reported, refer to them. Otherwise check the GPU solver log and its service status (C:\Windows\Temp\cudaSolver).
We96f8e1
GPU solution was not requested - running on the CPU only
This is an information regarding the usage of GPU solving.
The GPU solving was not activated and the optimisation will be carried out on CPU.
We97672e
GPU solution is enabled - attempting to solve on GPU
This is an information regarding the usage of GPU solving.
The GPU solving was activated and the software will use GPU solving if there aren’t any other issues.
We97dfe0
GPU solution was requested but is not installed - running on the CPU only
This is an information regarding the usage of GPU solving.
If you wish to optimise using GPU solving, make sure you have installed the GPU service. Further information regarding the installation and usage here.
W1ce059fa
One or more of the boundary conditions (Load, Moment, Acceleration, Pressure or Displacement) could not be found in the configuration file.
Please see which boundary condition in the explicit warning message!
The optimisation will continue without the unspecified boundary condition. Review the result as well as your input and adjust the model setup if necessary.
Please contact MSC Apex Support for further information.
W1cc2b4cd
The software versions of the local MSC Apex Generative Design and the remote MSC Apex Generative Design program do not fit together.
If you are using the Command Line execution, make sure to install the same release versions locally and remotely. All release versions are available at the Solutions Download Center.
The optimisation will fall back to local CPU solving and continue running.
For further information, please contact MSC Apex Support.
W1c3051d8
Mass calculation is incorrect.
If you are using the Command Line execution, make sure you have set a Density for all spaces in the Configuration File.
Please contact MSC Apex support.
W6e4e5290
Empty mesh in input file … . An input file contains no geometry.
If you are using the Command Line execution, make sure that only valid input files are considered in the optimisation. Check your input files and start the optimisation again.
W5c2f1240
Unable to compute centroid for Space/Mask … - using bounding box center instead
A “corrupt” STL/PLY file was supplied for a Mask named in the warning text. Depending on other mask settings (whether the surface is to be used / filled), different centroids / centers of gravity are computed. This warning indicates all those attempts have failed and instead the bounding box center is used.
This can happen if the input has degenerate triangles or is not a closed surface. Please check the input files or replace these if possible.
Please contact MSC Apex Generative Design support for further help.
W94d7c884
Restart file volume is magnitudes smaller than Design Space. Please check the scaling of the restart file and make sure it fits to the unit system of the model.
W1cb255fc
Unable to find file for optimisation space … .
If you are using the Command Line execution, add an STL-file that’s set as the optimisation space to the folder and start the optimisation anew.
Please contact MSC Apex Generative Design Support.
Wa8ec889b
Reconnection failed.
W42f987d5
Restart file found: … - Restarting at iteration …
The optimisation run was interrupted/restarted . The run will continue with iteration … as a starting point.
W1c88afc8
No defined value for the complexity was found in the configuration file.
The optimisation continues with the default value for the Complexity. If you want to change the value go to the Studies Tab and adjust the value.
W1c89362a
No value regarding the detail of the elements was found in the configuration file.
If you are using the Command Line execution, the detail was not set in the Configuration File. The optimisation will continue with the default value for the detail.
Please contact the MSC Apex Support.
Wb22daeb0
Fall back to CG Solver.
Connection to GPU solver was not possible. Falling back to CPU solving. This can happen in different situations:
The GPU Service is not installed. Please check if the GPU Service installation was successful by checking the computers services for “MSC Apex GD GPU Solver Engine 2020 Feature Pack 1 (port …)”.
The GPU Service is not running. Please have a look at your computers Services and make sure the “MSC Apex GD GPU Solver Engine 2020 Feature Pack 1 (port …)” is running.
The network interface is no longer active. This can happen if you are disconnecting from a network. Make sure that the network adapters in the computer Device Manager do not go into sleep mode to save power when disconnected.
W1ca0d86b
The setting for Shape Quality is missing in the configuration file.
If you are using the Command Line execution, make sure a Shape Qualityis set in the Configuration File. Supported are the types Preview, Balanced and Fine Tune. The optimisation will continue with the default option Balanced. If you would like to use another Shape Quality please define this in the Studies Tab/configuration file.
Please contact the MSC Apex Support.
W1ca4a4c1
The setting for Strut Density is missing in the configuration file.
If you are using the Command Line execution, make sure a Strut Density is set in the Configuration File. Supported are the types Dense, Medium and Sparse. The optimisation will continue with the default option Medium. If you would like to use another Strut Density please define this in the Studies Tab/Configuration File.
Please contact the MSC Apex Support.
Wc4fe85e2
BF15844446026 is deprecated, please remove in the configuration
Big Non-Design Spaces are considered correctly in the optimisation and have no influence. The additional Code is no longer necessary, please leave the code out of your models.
W3c2bc158
There are not as many GPUs available on the license server … as are recommended for this optimisation … .
There are multiple Events in the optimisation setup and equally many GPUs are recommended to enhance the calculation time. Adjust the number of GPUs or make more licenses available for the optimisation.
W3c2bc541
It is not possible to check out at least one GPU license.
There are no GPU license available . If you have GPU licenses, make sure they are available. If this problem is occurring although your having the required licenses please contact the MSC License support. If you would like to get GPU licenses please contact your MSC sales representative. The optimisation is falling back to CPU solving and will continue.
W3c2bc540
The available number of GPU licenses could not be checked out! The system is trying to checkout one less GPU license.
The System cannot find the defined number of GPU licenses. You can only use GPU solving if you have GPU licenses. Please contact your MSC Sales Representative for more information on how to get GPU licenses.
We7ec7c46
The number of maximal used GPUs (solverUsedGpuMax) is higher than the number of available GPUs.
If you are using the Command Line execution, adjust the number of solverUsedGpuMax and Restart the optimisation. Otherwise the optimisation will continue with less GPUs.
W1c9c8673
Not enough memory available.
The model is too large, complexity is too high for this optimisation model.
Adjust the Complexity and try a new optimisation run.
W1d175302
No volume greater than 50% found!
The optimisation model is insufficiently designed. The solver cannot find a satisfactory solution.
This can be a hint that the STL-file format is incorrect for a Restart or Start Space optimisation. It’s also possible that the input STL-file is defect. Please check the unit system and the quality of the input STL-file.
Another reason for this error can be an unsupported filename. There cannot be spaces, parenthesis and accents in the names – except for the SolidWorks STL-files. SolidWorks produces a specific name which our engine supports and is able to read.
The software supports binary STL-files and almost all ASCII files but not faultless.
For further questions please contact MSC Apex Support.
We8844d64
Remesh failed
Creating a remesh of the geometry failed. The optimisation will continue.
W9e73cb85
AutomaticFunctionalFacesDetection might be unstable, corrections have been applied.
The optimisation run will continue.
W1cbb4449
There is not enough memory (RAM) available for the optimisation to continue.
Please close other applications to free memory. The optimisation will retry to allocate the memory and continue running if enough memory could be allocated.
Otherwise, reduce the Complexity of your optimisation model (Study Tab).
W175a5d37
Unable to meet requested detail level. Minimum level: …
The model is too large, complexity is too high for this optimisation model.
The input level of detail cannot be reached. Adjust the detail value and try another optimisation run.
If you have added Advanced User Settings with adjusted iteration levels and Stress Goals, these are not chosen very well. Please adjust your model set up and try another optimisation run.
Please contact the MSC Apex Support.
W175bd3ad
Unable to meet level of detail.
The model is too large, complexity is too high for this optimisation model.
If you have added Advanced User Settings with adjusted iteration levels and Stress Goals, these are not chosen very well. Please adjust your model set up and try another optimisation run.
Please contact the MSC Apex Support.
We6f8522a
Config line is not UTF-8 encoded
The input of the Configuration File doesn’t meet the required coding standard. If you have entered wide-characters, please change these and try to start the optimisation again.
Please contact MSC Apex Generative Design support for further help.
W17419b31
Configuration file does not exist.
If you are using Command Line execution, make sure a Configuration File is available in the optimisation folder.
Please contact the MSC Apex Support.
W17421f47
Missing configuration name or ending.
If you are using Command Line execution, make sure a Configuration File with a valid name and file-ending is available in the optimisation folder.
Please contact the MSC Apex Support.
We131b33c
Only … GB free memory.
The system has not enough free memory (RAM) to create the FE-Matrix.
We109f304
A complexity of … (detail: …) is too high, and also a complexity of … (detail: …) would certainly be too high to pass the first iteration. A complexity of … (detail: …) is recommended.
The chosen complexity value is too high to be calculated on this machine. A certain maximum complexity value is recommended.
Ee109f304
We109f304 is handled as an error
The warning We109f304 causes a stop of the calculation.
Sometimes, this error can prevent an optimisation with a Start Space on the highest resolution level although the optimisation would be possible. Add disable.error.Ee109f304 to the Advanced User Settings to ingnore it.
E8b7af774
The Mask … was removed.
The Design Space has lost the connection to a Non-Design Space on which no boundary conditions are applied (former W8b7af774).
E86b9657
Start space volume is magnitudes bigger than design space. You might want to check start space scaling.
The Start Space STL-file is in a wrong unit system.
Only the SI-Unit system is supported for a Restart.
Ec3b1ac29
No fixed knots found.
The Design Space has lost the connection to one or more of the fixation(s). The model is no longer fixated and it doesn’t make sense to continue with the optimisation.
E8bb13ecb
The … was removed and the applied boundary constraints are not considered
The Design Space has lost the connection to the force/constraint application point. The model is no longer complete and it doesn’t make sense to continue with the optimisation.
In case you are using the symmetry option, have a look at your model setup. The forces and constraints must be applied on the part of the model in the direction of the positive coordinate system.
Ec9140297
Please don't overlay different Coordinate Systems that have fixation constraints.
Check your fixation constraints which refer to the local coordinate systems.
E1c9e4357
Missing iteration level … in config
The input of the Advanced User Settings is incomplete.
E1cbd48f4
Memory allocation error.
There is not enough working memory available. Adjust the Complexity to a lower value and restart the optimisation.
Ed35de27c
Last written PLY file could not be determined.
Check your available memory. If you don’t have enough available memory the result files cannot be written and the optimisation cannot continue. If you have sufficient memory, please contact the MSC Apex Support.
GPU Solving CUDA Solver Warnings & Errors
W5c7572a0
No operational GPU found for solving input (insufficient free memory).
Check the memory status of your GPU and terminate other programs that might affect the GPU memory.
W24850de8
Error Closing worker thread socket.
CUDA Solver is terminated although the optimisation is still running.
The optimisation will continue and fall back to local CPU solving.
Check the status of your CUDA Solver.
Please contact MSC Apex Support.
0 Comments