MSC Apex Generative Design might not visualize Non-Design Spaces using the Shape Quality “Preview”. The Non-Design Spaces are considered in the optimisation but because of the coarse resolution level of these iterations not visualized (fully). Choose another Shape Quality setting to run a complete optimisation and receive a full visualization.
MSC Apex Generative Design might generate different results while calculating in different unit systems due to inaccuracies/differences of decimal places.
MSC Apex Generative Design supports one solid using the User Interface. As a workaround the command line optimisation input can be influenced and multiple solids realised.
MSC Apex Generative Design supports one material for all spaces. As a workaround unsupported options can be added using the Advanced User Settings to define different materials.
“Symmetry" is not directly selectable in the User Interface but is available for the optimisation as an unsupported option using the Advanced User Settings. For more information have a look here.
"Restart" is not directly selectable in the User Interface but is available for the optimisation as an unsupported option using the Advanced User Settings. For more information have a look here.
MSC Apex Generative Design may ignore boundary conditions if a pressure load as well as other conditions are applied on the same surface. Pressure loads can only be applied on the specific surface where no other boundary conditions are active.