In this section you find information about occurring warnings and errors. As we are still gathering information on how/when warnings and errors occur and under which circumstances this site will constantly be updated with new information.

...

Information regarding the “Analysis Readiness” checks can be found here. Link

Please contact the MSC Apex Support (mscapex.support@mscsoftware.com) if a warning or error occurs which is not yet listed here or cannot be averted by applying the compiled help.

Wf9ae851b

“Probable reduction of the model is more than …% of the starting model.”

This is just a notification that the predicted reduction of the model is very high.

Further information here.

Wf9b42fd9

“Probable reduction of the model is more than …% of the starting model.”

This is just a notification that the predicted reduction of the model is very high.

Further information here.

Wf06bfce1

A material name was not set.

If you are using the Command Line execution execution, please make sure a name for the material is set in the Configuration File file.

Please contact MSC Apex Support.

...

Check the unit system of your Start Space. When using a Start Space the STL-file needs to be available in the same unit system as the optimisation was setup. Further information about a Restart here.

W1c05e9e6

Result data couldn't be projected onto the result geometry for certain polygons (black). The stresses and displacements cannot be viewed in certain areas.

...

No Solver IP was found in the configuration file.

The set up for GPU and/or Remote Solving is not complete. The optimisation will fall back to local CPU solving and continue running. The solver settings can be changed in the Application Settings - Generative Design Solver.

If you are running a Command Line optimisation, make sure the appropriate Solver IP is included in the Configuration File.

If further issues occur, please contact MSC Apex Support.

...

No Solver IP was found in the configuration file.

The set up for GPU and/or Remote Solving is not complete. The optimisation will fall back to local CPU solving and continue running. The solver settings can be changed in the Application Settings - Generative Design Solver.

If you are running a Command Line optimisation, make sure the appropriate Solver IP is included in the Configuration File.

If further issues occur, please contact MSC Apex Support.

...

No Solver Port setting was found in the configuration file.

The set up for GPU and/or Remote Solving is not complete. The optimisation will fall back to local CPU solving and continue running. The solver settings can be changed in the Application Settings - Generative Design Solver.

If you are running a Command Line optimisation, make sure the appropriate Solver Port IP is included in the Configuration File.

If further problems occur, please contact MSC Apex Support.

...

No Solver Port setting was found in the configuration file.

The set up for GPU and/or Remote Solving is not complete. The optimisation will fall back to local CPU solving and continue running. The solver settings can be changed in the Application Settings - Generative Design Solver.

If you are running a Command Line optimisation, make sure the appropriate Solver Port IP is included in the Configuration File.

If further problems occur, please contact MSC Apex Support.

W1cab408b

The software versions of the engine Engine and the solver CUDA Solver do not fit together.

Interne Meldung, für Apex und uns vor einer Release

No The connection to the extern external solver was not possible. The optimization will continue and fall back to local CPU solving.

Please contact MSC Apex Support.

W39fed060

The Matrix is too large for the GPU solver.

The GPU memory is too small for the model. The optimisation falls back to CPU calculation. Continue calculating on CPU or reduce the matrix by adjusting the model ( e.g. reduce the
Complexity).

W7004d2f0

Inexact match for space/mask …'s file name - this feature is deprecated and will be removed in future releases.

If you are using the Command Line execution, please make sure the full file name including the extension is written correctly into the Configuration File. The optimisation will continue but might not run in future releases.

If you have used the GUI to setup the model, this will be handled automatically.

W7aa7a778

Machining offset " << ident << " The Machining Allowance … is too small to be represented. Choose a bigger Machining Allowance so that a representation is possible.

W74bbc128

The Machining offset Allowance is much larger than design spaceDesign Space. Please check the unit dimensions in configuration Configuration File.

W2ab3f0d8

The Machining offset Allowance protrudes the build area box. Choose a smaller Machining Allowance.

W61379840

Meshfix warning …

...

Cannot check out GPU features.

To use GPU Solving an additional license is necessary. Please check your licenses in Options → License Manager or deactivate GPU solving in the Options → Application Settings - Generative Design Solver. The optimisation will fall back to local CPU solving and continue running.

...

The software versions of the local MSC Apex Generative Design and the remote MSC Apex Generative Design program do not fit together.

If you are using the Command Line execution, make sure to install the same release versions locally and remotely. All release versions are available at the Solutions Download Center.

...

Mass calculation is incorrect.

If you are using the Command Line execution, make sure you have set a Density for all spaces in the Configuration File.

Please contact MSC Apex support.

...

Empty mesh in input file … . An input file contains no geometry.

If you are using the Command Line execution, make sure that only valid input files are considered in the optimisation. Check your input files and start the optimisation again.

...

A “corrupt” STL/PLY file was supplied for a Mask named in the warning text. Depending on other mask settings (whether the surface is to be used / filled), different centroids / centers of gravity are computed. This warning indicates all those attempts have failed and instead the bounding box center is used.

...

Please contact MSC Apex Generative Design support for further help.

W94d7c884

Restart file volume is magnitudes smaller than design space. You might want to check restart file scalingDesign Space. Please check the scaling of the restart file and make sure it fits to the unit system of the model.

W1cb255fc

Unable to find file for optimisation space … .

...

Please contact MSC Apex Generative Design Support.

W2ae386d0 - überhaupt beim Kunden?

invalid reconnectionStrategy setting: Expected Default, AllShortestPaths or GreedyShortestPaths

W42f987d5

Restart file found: … - Restarting at iteration …Restart file found: " << this->restartFile << " - Restarting at iteration "<< this->restartIteration

The optimisation run was interrupted/restarted . The run will continue with iteration … as a starting point.

W1c88afc8

No defined value for the complexity was found in the configuration file.

The optimisation continues with the default value for the Complexity. If you want to change the value go to the Application Settings - Generative Design Solver and adjust the value.

...

No value regarding the detail of the elements was found in the configuration file.

If you are using the Command Line execution, the detail was not set in the Configuration File. The optimisation will continue with the default value for the detail.

...

Fall back to CG Solver.

Connection to GPU solver was not possible. Falling back to CPU solving. This can happen in different situations:

  • The GPU Service is not installed. Please check if the GPU Service installation was successful by checking the computers services for “MSC Apex GD GPU Solver Engine 2020 Feature Pack 1 (port …)”.

  • The GPU Service is not running. Please have a look at your computers Services and make sure the “MSC Apex GD GPU Solver Engine 2020 Feature Pack 1 (port …)” is running.

  • The network interface is no longer active. This can happen if you are disconnecting from a network. Make sure that the network adapters in the computer Device Manager do not go into sleep mode to save power when disconnected.

W1ca0d86b

The setting for Shape Quality is missing in the configuration file.

If you are using the Command Line execution, make sure a Shape Qualityis set in the Configuration File. Supported are the types Preview, Balanced and Fine Tune. The optimisation will continue with the default option Balanced. If you would like to use another Shape Quality please define this in the Studies Tab/configuration file.

Please contact the MSC Apex Support.

W1ca4a4c1

The setting for Strut Density is missing in the configuration file.

If you are using the Command Line execution, make sure a Strut Density is set in the Configuration File. Supported are the types Dense, Medium and Sparse. The optimisation will continue with the default option Medium. If you would like to use another Strut Density please define this in the Studies Tab/Configuration File.

Please contact the MSC Apex Support.

...

There are multiple Events in the optimisation setup and equally many GPUs are recommended to enhance the calculation time. Adjust the number of GPUs or make more licenses available for the optimisation.

...

It is not possible to check out at least one GPU license.

There are no GPU license available . If you have GPU licenses, make sure they are available. If this problem is occurring although your having the required licenses please contact the MSC License support. If you would like to get GPU licenses please contact your MSC sales representative. The optimisation is falling back to CPU solving and will continue.

...

The System cannot find the defined number of GPU licenses. You can only use GPU solving if you have GPU licenses. Please contact your MSC Sales Representative for more information on how to get GPU licenses.

We7ec7c46

The number of maximal used GPUs (solverUsedGpuMax) is higher than the number of available GPUs.

If you are using the Command Line execution, adjust the number of solverUsedGpuMax and Restart the optimisation. Otherwise the optimisation will continue with less GPUs.

W1c9c8673

Not enough memory available.

The model is too large, complexity is too high for this optimisation model.

Adjust the Complexity and try a new optimisation run.

...

This can be a hint that the STL-file format is incorrect for a Restart or Start Space optimisation. It’s also possible that the input STL-file is defect. Please check the unit system and the quality of the input STL-file.

...

For further questions please contact MSC Apex Support.

We8844d64

Remesh failed

Creating a remesh of the geometry failed. The optimisation will continue.

W1cbb4449

There is not enough memory (RAM) available for the optimisation to continue.

Please close other applications to free memory. The optimisation will retry to allocate the memory and continue running if enough memory could be allocated.

Otherwise, reduce the Complexity of your optimisation model (Application Settings - Generative Design Solver).

...

The input level of detail cannot be reached. Adjust the detail value and try another optimisation run.

If you have added Advanced User Settings with adjusted iteration levels and stress goals, these are not chosen very well. Please adjust your model set up and try another optimisation run.

...

The model is too large, complexity is too high for this optimisation model.

If you have added Advanced User Settings with adjusted iteration levels and Stress Goals, these are not chosen very well. Please adjust your model set up and try another optimisation run.

...

Configuration file does not exist.

If you are using Command Line execution, make sure a Configuration File is available in the optimisation folder.

...

Missing configuration name or ending.

If you are using Command Line execution, make sure a Configuration File with a valid name and file-ending is available in the optimisation folder.

Please contact the MSC Apex Support.

E8b7af774

“The Mask … was removed.”

The Design Space has lost the connection to a Non-Design Space on which no boundary conditions are applied (former W8b7af774).

FAQ: Tearing off of Non-Design Spaces

E86b9657

“Start space volume is magnitudes bigger than design space. You might want to check start space scaling”

The Start Space STL-file is in a wrong unit system.

Only the SI-Unit system is supported for a Restart.

Ec3b1ac29

“No fixed knots found.”

The Design Space has lost the connection to one or more of the fixation(s). The model is no longer fixated and it doesn’t make sense to continue with the optimisation.

FAQ: Tearing off of Non-Design Spaces

E8bb13ecb

“The … was removed and the applied boundary constraints are not considered”

The Design Space has lost the connection to the force/constraint application point. The model is no longer complete and it doesn’t make sense to continue with the optimisation.

FAQ: Tearing off of Non-Design Spaces

In case you are using the symmetry option, have a look at your model setup. The forces and constraints must be applied in the direction of the positive coordinate system of the model.

...

Check your fixation constraints which refer to the local coordinate systems.

E1c9e4357

Missing iteration level … in config

The input of the Advanced User Settings is incomplete.

E1cbd48f4

Memory allocation error.

There is not enough working memory available. Adjust the complexity to a lower value and restart the optimizationoptimisation.

GPU Solving CUDA Solver Warnings & Errors

...

Check the memory status of your GPU and terminate other programs that might affect the GPU memory.

W24850de8

Error Closing worker thread socket.

...