Warning Message: Probable reduction of the model is more than …% of the starting model.

This warning shows, that the chosen settings result in a high material loss and this is probably not reduction. This might not be what the user wantsanticipates. The %-value is an estimation of the volume reduction at the end of the optimization process . So it is an estimation of the amount of volume reduction between the starting design and of the iteration 64 considering the stress goal.The considering the chosen optimization setup.

  • If the design space is chosen very large in comparison to the boundary application points the user will expect such a behaviour and the optimization is exactly doing what it’s supposed to be.

  • If the design space is not that large, the model setup is probably not chosen very well

...

  • . There might be huge differences between the amount of forces and the

...

  • defined stress goal.

...

  • Have a look at the stresses and adjust your optimization setup because the optimization will most likely not result in the expected

...

  • geometry. Find information on how to change the parameters here.

...

  • Additionally, the model setup can result in a lost connection to the nondesign spaces

...

  • and therefore boundary conditions. In this case the optimization will

...

  • produce an error and

...

  • terminate the run. Please see the error

...

The warning regarding the lost percentage was implemented to help the user choose better settings and is a kind of early warning system for the user, that the chosen parameters are not well selected and that the optimization will not end in a satisfactory result in most casesat an early stage in the optimization to evaluate the optimization and choose better settings.