Update Links
The above mentioned Error Codes suggest that the model setup isn’t suitable and a good optimisation result isn’t going to be achieved.
The Error codes mention a removal of a mask and therefore the removal of boundary conditions which results in a termination of the optimisation model. Because of this removal the model is no longer complete and it doesn’t make sense to continue with the optimisation.
Reasons why Masks are tearing off:
either no force or displacement is applied on the defined Non-Design Space→ no stresses are available for the stress optimisation to prevent the material from being reduced
or the force applied is too/very small compared to the optimisation target
or the additional fixation is not needed for the defined boundary conditions and optimisation constraints
Steps to prevent this behaviour:
Prevent the tearing off by:
increasing the Complexity → more elements are available and a finer model is possible (calculation effort increases!)
reducing the optimisation stress goal
increasing the applied force so that the stresses and therefore the relevance of the Nondesign space is increased
creating an extra load case in which fixations and loads are switched
Either it is a design proposal you can accept/want to achieve in order to reduce the number of fixation points
To reduce the number of fixations, the fixation has to be applied on all Nondesign spaces at once as one boundary condition (multi-selection)
Thus individual Fixations can tear off without an occurring error
Boundary condition multiselection of Nondesign spaces to enable tearing off of Fixations.
0 Comments