OUTDATED VERSION. Follow the link for the latest version: https://www.hexagonmi.com/MSC-Apex-Generative-Design/help

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 6 Next »

  • When you recognize that your optimization result is growing in an inappropriate way, than your optimization went wrong

  • The main reason is that the nondesign spaces on which the structural loads are applied tear off and lose the connection

    • This results in iterations where 0 MPa stress occur (see picture below)

  • In the following iterations the model is growing again due to zero stress

    • If its connect again with the Nondesign space a stress will appear again

Solution:

  • The occuring stress doesn’t fit to the optimization goal

    • Lower the optimization goal

    • Increase the applied structural loads

    • Increase the Complexity for a higher resolution

    • Change strut density from sparse to balanced or dense

  • No labels