Three remote loads are created (Force - Moment 1, Force - Moment 2 and Force - Moment 3) on the shown surfaces with the given values in the tables.

Name

Force/Moment/Pressure/Gravity

Direction (depending on local coordinate system)

Value in N/Nmm

Force - Moment 1

Force on faces

z (proposed center is point of application)

-5000

...

Force - Moment 2 is applied on the other two surfaces. The point of application of this remote Force can set up by determining a point regarding the global coordinate system.

Name

Force/Moment/Pressure/Gravity

Direction (depending on local coordinate system)

Value in N/Nmm

Force - Moment 2

Force on faces

z (Point of Application [-100;0;-15])

-2000

...

Force - Moment 3 is applied on the same surfaces like the first Force. This new Load is referring to the local coordinate system created earlier.

 

Name

Force/Moment/Pressure/Gravity

Direction (depending on local coordinate system)

Value in N/Nmm

Force - Moment 3

Force on faces

x (local coordinate system 1; proposed center is point of application)

7000

...

One Constraint which includes all six Non-Design Spaces at the bottom of the structure is created:

Name

Direction

Constraint 1

x, y, z (=0)

Under Displacement Constraints a “clamped” constraint can be chosen, which locks translations in all three directions. On the left side of the Tool the relevant geometry choice can be selected. In this case the inner surfaces of the Non-Design Spaces are selected to attach the constraints as shown in the picture below.

...

If on all functional surfaces a Machining Allowance is applied, with the Advances User Settings the automatic growth of Non-Design Spaces can be deactivated with the following command:

configuration.autodetection.positiveNonDesignDirection = false

The automatic growth of Non-Design Spaces is activated as the default in case that no Machining Allowances are applied. The automatic growth of Non-Design Spaces can sometimes lead to some issues. More information here.

...

You can go back to the model setup by clicking the Exit button in the right bottom corner.

The whole MSC Apex Generative Design project with all results can be downloaded here:

View file
nameGD_Bracket_2021-2.7z
View file
nameGD-Bracket_2021-2_Complexity.7z
View file
nameGD-Bracket_2021-2_KeepNonDesigns.7z
View file
nameGD_Bracket_2021-2_ESSF.7z

You might also be interested in these tutorials:

...