Some voxel elements cannot be reached by any tool (especially for casting). Please contact the support if this leads to unsatisfying results.

W22501763

E7f716c48

This Error is only produced after another Error was encountered. The optimisation algorithm tried to continue despite the previous Error but could not continue. The optimisation fails with this Error although the primary Error is the reason for the terminated optimisation.

E4ebe0a20

Projected memory requirement exceeds available memory - complexity … (detail …) is too high. Theoretical limit: complexity … (detail …), recommended: complexity … (detail …)

The chosen complexity value is too high to be calculated on this machine. A certain maximum complexity value is recommended. Have a look here.

Eb20f3415

boundary condition is missing elements

A Non-Design Space was removed and the applied boundary conditions are not considered

The Design Space has lost the connection to the force/constraint application point. The model is no longer complete and it doesn’t make sense to continue with the optimisation.

Make sure that the Keep Non Design function is activated. Increase the Complexity or increase the Safety Factor.

Eb20f3980

Missing config entry …

The configuration file is missing an entry or command. Please check your entries in the Advanced User Settings or if you are using the Command Line Optimisation please check the Configuration File. You can find all commands for the Advanced User Settings here and the Configuration File here.

E58799450

unexpected error writing file file_name.ply:

One of the result files cannot be written. This can happen while using parallelization (default). This can be resolved by adding following Advanced User Settings commands:

...

process.workers = 1

E724493a8

Unable to open file … for writing

There are no privileges to access a file which is needed. Please check where the project folder is placed in which all the results are written. Network drives and cloud storage (e.g. OneDrive) are not recommended.

E3ee97ff0

supportReductionIntensity … is out of bounds 0-10.

Please adjust the Intensity value of the Support Reduction according to the boundaries.

E449a19a0

invalid supportReductionMode … expected off, passive, reactive or active.

Please set the Support Reduction Mode to one of the supported modes.

E4a364e88

missing / incompatible strutDensity setting for use with support avoidance.

If you are using the Support Reduction, you need to define a Strut Density.

Eb20f33c1

LicenseConstraintException    failed to acquire … count … instances of … feature.

A license for the GD Engine and/or the GPU calculation couldn’t be acquiered. Please check your licenses.

E0850d340

Attempted to write a checkpoint on unpaused job.

Restart file could not be written at this point in the optimisation. Please have a look at the prior error code which shows the primary reason for the failed optimisation.

E16808658

Legacy config format is disabled.

Please export the Scenario again (version 2022.1 or newer) to generate the supported json file format.

W1a123238

Symmetry coordinate systems are deprecated and will be removed in 2022.4 release. Use configuration.principalCoordinateSystem instead.

This can only happen when the configuration file was manually adjusted and a command line optimisation executed. The symmetry coordinate system has been replaced by a general principal coordinate system. Have a look at the Configuration File page for further information.

E18f03ac8

Given symmetry coordinate system and principal coordinate system conflict.

This can only happen when the configuration file was manually adjusted and a command line optimisation executed. The symmetry coordinate system has been replaced by a general principal coordinate system. Have a look at the Configuration File page for further information.

W2cc566c0

Fixed … reshaping error(s) - boundary violations … threshold exceeded …

Information message that the algorithm corrected some errors in the file. The optimisation continues as before.

E79aa1a40

Fractured design space - make sure the model consists of only a single, connected body.

Occurs mainly if no Interface is placed between Design Space and Retained Volume.

E413ccf6b

point mass … refers to non-existing geometry …

Make sure the point mass refers to a geometry.

E72deb9d2

Using RBE2 point masses with linear-static analyses is not supported yet

RBE2 isn’t supported for static load cases / events yet. It is supported for frequency load cases / events.

E7d830f0a

Point masses without position are not supported yet

A point mass has to have a defined position.

E40a1d044

Nastran directory could not be created

Please contact the MSC support.

E56b33469

Unable to export Nastran model: Incompatible FEA setup

Please contact the MSC support.

E56b33470

Unable to export Nastran model: not enough data modes

Please contact the MSC support.

E61ad1352

NastranExport.h5 formatting error: Path << path << not found in nastran data sets

Please contact the MSC support.

E2f8f1750

Nastran requires paths to not contain space characters under GNU/Linux

Please do not use space characters in paths under Linux.

E4fb68977

symmetry not supported with frequency conditions

The hard symmetry isn’t supported for eigenfrequency optimisations.

E0b564a04

Unknown shapeQuality …

The shapeQuality name in the configuration file is unknown.

E1cb2aef0

Please use nast20233(.exe) (or the matching executable for your installed nastran version) for frequency analysis

nast20233w.exe isn’t suitable for the frequency optimisation

E26a56588

failed to execute nastran sub process

For eigenfrequency optimisations MSC Nastran is called in the background. In this case Nastran cannot be executed.

E2d0825a0

failed to run nastran successfully

For eigenfrequency optimisations MSC Nastran is called in the background. In this case Nastran cannot be executed sucessfully.

E2acb9470

mesh conversion from amendate to cgal failed

The smoothing algorithm failed. Please contact MSC support.

E2b0895a0

galMesh have poligones with more that three vetices

The smoothing algorithm failed. Please contact MSC support

E2b3625b0

out of bounds

The smoothing algorithm failed. Please contact MSC support

E4badd760

Requested nastran operation but did not specify nastran service. Please set env variable 'EMENDATE_SERVICE_NASTRAN' to point to your nastran binary.

If you want to execute a frequency optimisation directly in the command line, you have to set a environment variable which points to the nast20233.exe

EMENDATE_SERVICE_NASTRAN

C:\Program Files\MSC.Software\MSC_Nastran\2023.2\bin\nast20232.exe

E4badd761

envName … does not point to a regular file

Please check the environment variable for the MSC Nastran installation

Eb20f309c

OperatorFailure operator … crashed

A specific operator crashed. Please contact the MSC support.

E6f543a5c

Cannot inflate geometry with zero vertices

This can occur to a current limitation. Please make sure that a point load or a displacement constraint on a point is not applied at the edge of an interface. Increase the Interface or change the load to a surface instead.

E6d49ffc0

Unfeasible FEM setup: Missing fixation in one or more directions

Check the model set-up. All 3 degrees of freedom have to be constraintpoint of application missing for RBE2/RBE3 condition …

There is no point of application set for a boundary condition with a RBE2 / RBE3 element. Make sure a dummy load is created with a force value.

W3efb0cf5

tool … is facing the wrong way with respect to symmetry planes

Hard symmetry is active and one draw direction is normal to the symmetry plane and redundant.

W7f2ab81d

rotational fixation on … ineffective - select tying mode RBE2

Rotational degrees of freedom can be only unconstraint if a RBE2 element is used.

W03318c60

Missed … voxels marked for erosion

Some voxels in the background couldn’t be reached for erosion. Please contact the support if this happens several times.

E7f716c48

This Error is only produced after another Error was encountered. The optimisation algorithm tried to continue despite the previous Error but could not continue. The optimisation fails with this Error although the primary Error is the reason for the terminated optimisation.

E4ebe0a20

Projected memory requirement exceeds available memory - complexity … (detail …) is too high. Theoretical limit: complexity … (detail …), recommended: complexity … (detail …)

The chosen complexity value is too high to be calculated on this machine. A certain maximum complexity value is recommended. Have a look here.

Eb20f3415

boundary condition is missing elements

A Non-Design Space was removed and the applied boundary conditions are not considered

The Design Space has lost the connection to the force/constraint application point. The model is no longer complete and it doesn’t make sense to continue with the optimisation.

Make sure that the Keep Non Design function is activated. Increase the Complexity or increase the Safety Factor.

Eb20f3980

Missing config entry …

The configuration file is missing an entry or command. Please check your entries in the Advanced User Settings or if you are using the Command Line Optimisation please check the Configuration File. You can find all commands for the Advanced User Settings here and the Configuration File here.

E58799450

unexpected error writing file file_name.ply:

One of the result files cannot be written. This can happen while using parallelization (default). This can be resolved by adding following Advanced User Settings commands:

process.workers = 1

E724493a8

Unable to open file … for writing

There are no privileges to access a file which is needed. Please check where the project folder is placed in which all the results are written. Network drives and cloud storage (e.g. OneDrive) are not recommended.

E3ee97ff0

supportReductionIntensity … is out of bounds 0-10.

Please adjust the Intensity value of the Support Reduction according to the boundaries.

E449a19a0

invalid supportReductionMode … expected off, passive, reactive or active.

Please set the Support Reduction Mode to one of the supported modes.

E4a364e88

missing / incompatible strutDensity setting for use with support avoidance.

If you are using the Support Reduction, you need to define a Strut Density.

Eb20f33c1

LicenseConstraintException    failed to acquire … count … instances of … feature.

A license for the GD Engine and/or the GPU calculation couldn’t be acquiered. Please check your licenses.

E0850d340

Attempted to write a checkpoint on unpaused job.

Restart file could not be written at this point in the optimisation. Please have a look at the prior error code which shows the primary reason for the failed optimisation.

E16808658

Legacy config format is disabled.

Please export the Scenario again (version 2022.1 or newer) to generate the supported json file format.

W1a123238

Symmetry coordinate systems are deprecated and will be removed in 2022.4 release. Use configuration.principalCoordinateSystem instead.

This can only happen when the configuration file was manually adjusted and a command line optimisation executed. The symmetry coordinate system has been replaced by a general principal coordinate system. Have a look at the Configuration File page for further information.

E18f03ac8

Given symmetry coordinate system and principal coordinate system conflict.

This can only happen when the configuration file was manually adjusted and a command line optimisation executed. The symmetry coordinate system has been replaced by a general principal coordinate system. Have a look at the Configuration File page for further information.

W2cc566c0

Fixed … reshaping error(s) - boundary violations … threshold exceeded …

Information message that the algorithm corrected some errors in the file. The optimisation continues as before.

E79aa1a40

Fractured design space - make sure the model consists of only a single, connected body.

Occurs mainly if no Interface is placed between Design Space and Retained Volume.

E413ccf6b

point mass … refers to non-existing geometry …

Make sure the point mass refers to a geometry.

E72deb9d2

Using RBE2 point masses with linear-static analyses is not supported yet

RBE2 isn’t supported for static load cases / events yet. It is supported for frequency load cases / events.

E7d830f0a

Point masses without position are not supported yet

A point mass has to have a defined position.

E40a1d044

Nastran directory could not be created

Please contact the MSC support.

E56b33469

Unable to export Nastran model: Incompatible FEA setup

Please contact the MSC support.

E56b33470

Unable to export Nastran model: not enough data modes

Please contact the MSC support.

E61ad1352

NastranExport.h5 formatting error: Path << path << not found in nastran data sets

Please contact the MSC support.

E2f8f1750

Nastran requires paths to not contain space characters under GNU/Linux

Please do not use space characters in paths under Linux.

E4fb68977

symmetry not supported with frequency conditions

The hard symmetry isn’t supported for eigenfrequency optimisations.

E0b564a04

Unknown shapeQuality …

The shapeQuality name in the configuration file is unknown.

E1cb2aef0

Please use nast20233(.exe) (or the matching executable for your installed nastran version) for frequency analysis

nast20233w.exe isn’t suitable for the frequency optimisation

E26a56588

failed to execute nastran sub process

For eigenfrequency optimisations MSC Nastran is called in the background. In this case Nastran cannot be executed.

E2d0825a0

failed to run nastran successfully

For eigenfrequency optimisations MSC Nastran is called in the background. In this case Nastran cannot be executed sucessfully.

E2acb9470

mesh conversion from amendate to cgal failed

The smoothing algorithm failed. Please contact MSC support.

E2b0895a0

galMesh have poligones with more that three vetices

The smoothing algorithm failed. Please contact MSC support

E2b3625b0

out of bounds

The smoothing algorithm failed. Please contact MSC support

E4badd760

Requested nastran operation but did not specify nastran service. Please set env variable 'EMENDATE_SERVICE_NASTRAN' to point to your nastran binary.

If you want to execute a frequency optimisation directly in the command line, you have to set a environment variable which points to the nast20233.exe

EMENDATE_SERVICE_NASTRAN

C:\Program Files\MSC.Software\MSC_Nastran\2023.2\bin\nast20232.exe

E4badd761

envName … does not point to a regular file

Please check the environment variable for the MSC Nastran installation

Eb20f309c

OperatorFailure operator … crashed

A specific operator crashed. Please contact the MSC support.

E6f543a5c

Cannot inflate geometry with zero vertices

This can occur to a current limitation. Please make sure that a point load or a displacement constraint on a point is not applied at the edge of an interface. Increase the Interface or change the load to a surface instead.

E6d49ffc0

Unfeasible FEM setup: Missing fixation in one or more directions

Check the model set-up. All 3 degrees of freedom have to be constraint.

E2480e78f

ressure / acceleration loads cannot be tied with RBE2/RBE3

RBE2 / RBE3 can only be used for forces or displacement constraints.

E3789b912

tool … is facing the wrong way with respect to symmetry planes. Make sure all tools draw towards the positive side of all symmetry planes

Hard symmetry is active and one draw direction is normal to the symmetry plane and redundant.

E6a85815e

RBE3 tyings cannot support fixations

RBE3 elements do not support displacement constraint. This makes the FE matrix unsolvable.

E00d7aaa4

unable to create temporary directory / file exists in its place …

File system error. Please check the path.

E5f09e875

RBE-tied boundary condition is missing nodes

RBE element lost all voxel elements. Please contact the support.

E6eb64648

build space DesignSpace_machiningCut does not exist 

The Design Space could not be created. Please check the initial geometry for faults. Set the machining allowance of interfaces to a value of 0.

E6062c240

no design space(s) specified

The Design Space could not be created or is not specified in the configuration file. Please check the initial geometry for faults. Set the machining allowance of interfaces to a value of 0.

Escalations

E45ca3ab0

W45ca3ab0

Start candidate volume far exceeds design volume - check scaling.One reason for a large difference between the volumes is the unit system. Make sure the start space geometry is in SI units and start the optimisation anewscaling.

One reason for a large difference between the volumes is the unit system. Make sure the start space geometry is in SI units and start the optimisation anew.

E293fa8dc

W293fa8dc

Invalid RBE2 constellation - overlapping nodes

Several RBE2 elements cannot be applied on the same spot for the same Event. This makes the FE matrix unsolvable.

E32a6e878

W32a6e878

Insufficient complexity for maxThickness. Suggested minimum complexity is …

For a chosen max. Thickness value the Complexity needs to be high enough to represent the desired structure with enough voxel elements in the background. Please increase the Complexity value or the max. Thickness value.

GPU Solving CUDA Solver Warnings & Errors

...