Remove and replace symmetry coordinate system

The Configuration File contains all information necessary for the algorithm to run through the optimisation. It is subdivided into different areas regarding the Configuration, Schedule, Material, Failure Criterion, Event, Boundary Conditions, Design, Geometry, Machining Allowance, Non-Design Spaces and Coordinate System. The file is written in the JSON-file format.

...

applicationRequest

OptimizationLoop

Indicates that the regular optimisation loop is executed

engine_version

2022.34

Indicates the version number with which the configuration file was created

...

configuration.offsetSpace

Geometry used for the intersection with the Design Space to receive the print geometry

configuration.buildSpace

Geometry used for the intersection with the Design Space to receive the nominal geometry

configuration.principalCoordinateSystem

Coordinate system on which all direction-dependent functions are based, such as the symmetry, the material coordinate system and the build direction.

configuration.complexity

Defines how complex the design is getting. More information here.

configuration.eigenThreads

Number of CPU threads that can be used to build the matrix. At least two cores should always remain free. We recommend using 2-6 threads.

configuration.maxConcurrentGPUSolvers

Maximum number of GPUs used by the optimisation (support GPUs: Nvidia Quadro Graphics Cards supported by CUDA Driver)

configuration.solver.<name>.strategy

InternalCPU: CPU based solver

ExternLegacy: External (GPU) solver

configuration.solver.<name>.host

 

IP of the external solver, localhost for the same workstation. IP for cloud, for what the matrix is built locally and sent to the calculation unit. Large amounts of data can be moved with a corresponding amount of time.

configuration.solver.<name>.port

Port which is used to access the CudaSolver. This can be selected arbitrarily, according to the specified value when starting the solver. (The default port for the Cuda service is 42001).

configuration.symmetry.x

configuration.symmetry.y

configuration.symmetry.z

x-axis as symmetry plane (Y-Z-Plane)

y-axis as symmetry plane (X-Z-Plane)

z-axis as symmetry plane (X-Y-Plane)

configuration.symmetry.coordinateSystem

If the symmetry is to refer to a local coordinate system, the following command must also be entered (Coordinate_system_1 is the name of the local coordinate system and can vary)

automaticFunctionalFacesDetection.positiveNonDesignDirection=true

 

 

false

Functional Surfaces are automatically detected. These areas grow during an optimisation to guarantee sharp edges and functional surfaces after the intersection.

If all functional surfaces have a Machining Allowance applied to them, this option should be deactivated.

configuration.unitSystem

Used unit system

...

In the Coordinate System section all used coordinate systems are listed and defined. All Coordinate System are based on the Principal Coordinate System that is always written to the configuration file.

coordinateSystem.<name>.alpha

coordinateSystem.<name>.beta

coordinateSystem.<name>.gamma

The coordinate system is located/orientated with coordinate values and Euler angles regarding the global coordinate system.

coordinateSystem.<name>.origin.x

coordinateSystem.<name>.origin.y

coordinateSystem.<name>.origin.z

The coordinate system has a point of origin.

...