The optimisation parameters are selected in the Studies Area as well.
Manufacturing Method: Generic AM
Failure Criteria: Von Mises
Safety Factor: 6,4
Select the Strut Density: Medium
Select the Shape Quality: Balanced
Set the Complexity Setting: 10
...
Don’t forget to save the project!
...
If all data is correct, the optimisation can be started and tracked in the Post Processing. The Analysis Readiness function checks if all information is provided and the optimisation can start.
...
All result iterations are displayed as soon as they are available. Furthermore, you are able to stop the optimisation in this selection area. However, a Restart is not directly possible.
...
You can check the status of the optimisation in the GD Status and get more information on Warning and Error messages. This can be done directly in the Post-Processing as well as in the Studies tab for an optimisation that has already run.
...
You can always change the Strut Density, Stress Goal and Complexityto influence the results and try out different options
The Complexitycan be increased for a higher resolution and more detailed result (increased calculation time!)
The Strut Densityinfluences the structures which are formed during optimisation
...
The whole MSC Apex Generative Design project with all results can be downloaded here:
View file | ||
---|---|---|
|
You might also be interested in these tutorials:
...