You can find Warning & Error codes displayed in the Studies tab by double clicking on the Generative Design Status or in the log files in the result folder in your workspace (log_error.log & log_warning.log).
...
This is an information regarding the usage of GPU solving. To use GPU Solving an additional license is necessary. Please check your licenses in Options → License Manager or deactivate GPU solving in the Options → Application Settings - Generative Design Solver.
...
Time estimation has become inconsistent, expect inaccuracies.
For Restarts and Two-Stage Optimisations the time estimation is inaccurate.
...
This might occur while performing a Command Line optimisation. The defined build space geometry is not defined as the design geometry. Therefore, the geometry needed for the intersection is not available and thus no intersection geometry is available. Please adjust the Configuration File.
W2f07aa98
Geometry … is not used by anything
This might occur while performing a Command Line optimisation. A geometry is not used in the optimisation. Please adjust the Configuration File.
W38a529d0
Failure criterion … is not used by anything
This might occur while performing a Command Line optimisation. The Failure Criterion is not used in the optimisation. Please adjust the Configuration File.
W6c825a00
Material is not valid. Condition 1 failed for Isotropic material …
W6c825a01
Material is not valid. Condition 2 failed for Isotropic material …
W6c825b00
Material is not valid. Condition 1 failed for transversal isotropic material …
W6c825b01
Material is not valid. Condition 2 failed for transversal isotropic material …
W6c825b02
Material is not valid. Condition 3 failed for transversal isotropic material …
W6c825b03
Material is not valid. Condition 4 failed for transversal isotropic material …
...
W6c825b04
Material is not valid. Condition 5 failed for transversal isotropic material …
W6c825b06
Material is not valid. Condition 7 failed for transversal isotropic material …
W6c825c00
Material is not valid. Condition 1 failed for orthotropic material …
W6c825c01
Material is not valid. Condition 2 failed for orthotropic material …
W6c825c02
Material is not valid. Condition 3 failed for orthotropic material …
W6c825c03
Material is not valid. Condition 4 failed for orthotropic material …
W6c825c04
Material is not valid. Condition 5 failed for orthotropic material …
W6c825c05
Material is not valid. Condition 6 failed for orthotropic material …
W6c825c06
Material is not valid. Condition 7 failed for orthotropic material …
W6c825c07
Material is not valid. Condition 8 failed for orthotropic material …
W6c825c08
Material is not valid. Condition 9 failed for orthotropic material …
W6c825c09
Material is not valid. Condition 10 failed for orthotropic material …
W6c825c10
Material is not valid. Condition 11 failed for orthotropic material …
W6c825c11
Material is not valid. Condition 12 failed for orthotropic material …
W6c825c12
Material is not valid. Condition 13 failed for orthotropic material …
...
Please change the material values according to the valid material conditions.
W0f25e2a0
Failure criterion Tsai Wu is not valid. One value is lower or equal zero for material …
Please change the material values according to the valid material conditions.
W7c709bf0
Failure criterion Tsai Wu is not valid. One value is lower or equal zero, or for Fxy, F_yz and F_zx not between -1 and 1 for material …
Please change the material values according to the valid material conditions.
W7b99b450
Failure criterion Tsai Hill is not valid. One value is lower or equal zero for material …
Please change the material values according to the valid material conditions.
W760ca740
Failure criterion Tsai Hill is not valid. One value is lower or equal zero for material …
Please change the material values according to the valid material conditions.
W658f5544
Adding autogenerated interface for boundary condition …
...
A Non-Design Space was removed and the applied boundary conditions are not considered
The Design Space has lost the connection to the force/constraint application point. The model is no longer complete and it doesn’t make sense to continue with the optimisation.
...
Fractured design space - make sure the model consists of only a single, connected body.
Occurs mainly if no Interface is placed between Design Space and Retained Volume.
...
Using RBE2 point masses with linear-static analyses analysis is not supported yet
RBE2 isn’t supported for static load cases / events yet. It is supported for frequency load cases / events.
...
The smoothing algorithm failed. Please contact MSC support.
E2b0895a0
galMesh have cgalMesh has poligones with more that than three veticesvertices
The smoothing algorithm failed. Please contact MSC support.
E2b3625b0
out of bounds
The smoothing algorithm failed. Please contact MSC support
...
Check the model set-up. All 3 degrees of freedom have to be constraint.
E2480e78f
ressure pressure / acceleration loads cannot be tied with RBE2/RBE3
...