You can find Warning & Error codes displayed in the Studies tab by double clicking on the Generative Design Status or in the log files in the result folder in your workspace (log_error.log & log_warning.log).
...
Information regarding the “Analysis Readiness” checks can be found here.
W5754bb78
GPU solver was not requested, using CPU solver only.
This is an information regarding the usage of GPU solving. The GPU solving was not activated.
W75eebb60
GPU computation was requested but is unavailable due to license limitations, using CPU solver only.
This is an information regarding the usage of GPU solving. To use GPU Solving an additional license is necessary. Please check your licenses in Options → License Manager or deactivate GPU solving in the Options → Application Settings - Generative Design Solver.
...
GPU computation was requested but no devices were found, using CPU solver only.
...
GPU computation was requested, using up to … GPU(s).
W255de448
Found … voxels outside of valid design space … removed them.
Optimization run continues.
Please contact MSC Apex Support.
W244ff728
Cannot map voxel …
The loads and boundary conditions could not be mapped to the voxel model and might not be considered in the optimisation anymore. LBCs should always be applied to Non-Design Spaces. These ensure a correct consideration of the LBCs during the optimisation.
W6f682328
Cannot copy output file. … does not exist as regular file
...
Time estimation has become inconsistent, expect inaccuracies.
For Restarts and Two-Stage Optimisations the time estimation is inaccurat.
...
There are two possible reasons for this warning:
The available memory cannot be detected because of the operating system.
There isn’t even enough memory available to let the optimisation start.
Make sure that there is more memory available or reduce the complexity.
...
Retained volumes occupy a significant portion of design space … volume 50% which increases the calculation time as well as the needed memory. Please reduce the complexity to reduce the calculation time and memory. Retained volumes will occupy about … GB of memory with current settings.
...
Unable to compute centroid for geometry … using bounding box center instead
A “corrupt” STL/PLY file was supplied for a Mask named in the warning text. Depending on other mask settings (whether the surface is to be used / filled), different centroids / centers of gravity are computed. This warning indicates all those attempts have failed and instead the bounding box center is used.
This can happen if the input has degenerate triangles or is not a closed surface. Please check the input files or replace these if possible.
W2e4e8b88
boundary condition is dislodged - no active elements …
...
The defined coordinate system … is not used by anything in the configuration file and will not be considered in the optimisation.
W41d43530
Missing density for space … setting to …
The density is set to the value listed in the warning message.
W1fb6cc10
Config entry 'calculationType' is deprecated, please use 'shapeQuality' instead.
...
This might occur while performing a Command Line optimisation. The defined build space geometry is not defined as the design geometry. Therefore, the geometry needed for the intersection is not available and thus no intersection geometry is available. Please adjust the Configuration File.
W2f07aa98
Geometry … is not used by anything
This might occur while performing a Command Line optimisation. A geometry is not used in the optimisation. Please adjust the Configuration File.
W38a529d0
Failure criterion … is not used by anything
This might occur while performing a Command Line optimisation. The Failure Criterion is not used in the optimisation. Please adjust the Configuration File.
W6c825a00
Material is not valid. Condition 1 failed for Isotropic material …
W6c825a01
Material is not valid. Condition 2 failed for Isotropic material …
W6c825b00
Material is not valid. Condition 1 failed for transversal isotropic material …
W6c825b01
Material is not valid. Condition 2 failed for transversal isotropic material …
W6c825b02
Material is not valid. Condition 3 failed for transversal isotropic material …
W6c825b03
Material is not valid. Condition 4 failed for transversal isotropic material …
W6c825b05
Material is not valid. Condition 6 failed for transversal isotropic material …
W6c825b04
Material is not valid. Condition 5 failed for transversal isotropic material …
W6c825b06
Material is not valid. Condition 7 failed for transversal isotropic material …
W6c825c00
Material is not valid. Condition 1 failed for orthotropic material …
W6c825c01
Material is not valid. Condition 2 failed for orthotropic material …
W6c825c02
Material is not valid. Condition 3 failed for orthotropic material …
W6c825c03
Material is not valid. Condition 4 failed for orthotropic material …
W6c825c04
Material is not valid. Condition 5 failed for orthotropic material …
W6c825c05
Material is not valid. Condition 6 failed for orthotropic material …
W6c825c06
Material is not valid. Condition 7 failed for orthotropic material …
W6c825c07
Material is not valid. Condition 8 failed for orthotropic material …
W6c825c08
Material is not valid. Condition 9 failed for orthotropic material …
W6c825c09
Material is not valid. Condition 10 failed for orthotropic material …
W6c825c10
Material is not valid. Condition 11 failed for orthotropic material …
W6c825c11
Material is not valid. Condition 12 failed for orthotropic material …
W6c825c12
Material is not valid. Condition 13 failed for orthotropic material …
W6493a120
The configuration file entry 'solverMaxMemory' is deprecated, please use 'complexity' instead.
W1b158cd8
Unfeasible FEM setup: Insufficient … fixed DOF.
...
The resolution command is higher prioritised and outweighs the Complexity input.
W25081f18
Failure criterion Von Mises is not valid. The Tensile Strength is lower or equal zero for material …
Please change the material values according to the valid material conditions.
W0f25e2a0
Failure criterion Tsai Wu is not valid. One value is lower or equal zero for material …
Please change the material values according to the valid material conditions.
W7c709bf0
Failure criterion Tsai Wu is not valid. One value is lower or equal zero, or for Fxy, F_yz and F_zx not between -1 and 1 for material …
Please change the material values according to the valid material conditions.
W7b99b450
Failure criterion Tsai Hill is not valid. One value is lower or equal zero for material …
Please change the material values according to the valid material conditions.
W760ca740
Failure criterion Tsai Hill is not valid. One value is lower or equal zero for material …
Please change the material values according to the valid material conditions.
W658f5544
Adding autogenerated interface for boundary condition …
...
This will happen for every displacement constraint because the interface surface and the constraint surface do not have to be the same.
E7f716c48
This Error is only produced after another Error was encountered. The optimisation algorithm tried to continue despite the previous Error but could not continue. The optimisation fails with this Error although the primary Error is the reason for the terminated optimisation.
E4ebe0a20
Projected memory requirement exceeds available memory - complexity … (detail …) is too high. Theoretical limit: complexity … (detail …), recommended: complexity … (detail …)
...
W5fa5cf20
Some events are missing preserved fixations, attempting to compensate by setting preserve on …
The optimisation will continue to run with the changes mentioned above. If these changes are not representing the model set up you anticipated, please adjust your model set up in the “Keep Non-Design Spaces” panel.
W5acd8220
Some events are missing fixations.
Adjust your model set up so that every Event has fixations in all three main directions (or local coordinate systems main direction) included.
Eb20f3415
boundary condition is missing elements
A Non-Design Space was removed and the applied boundary conditions are not considered
The Design Space has lost the connection to the force/constraint application point. The model is no longer complete and it doesn’t make sense to continue with the optimisation.
Make sure that the Keep Non Design function is activated. Increase the Complexity or increase the Safety Factor.
Eb20f3980
Missing config entry …
The configuration file is missing an entry or command. Please check your entries in the Advanced User Settings or if you are using the Command Line Optimisation please check the Configuration File. You can find all commands for the Advanced User Settings here and the Configuration File here.
E0d03bf38
Unable to resolve input file name statistics.csv
This may occur if an optimisation is started with Advanced User Settings with which only 1 or 2 iterations should be calculated. If this is the case please add the following Advanced User Settings commands:
schedule.level.3.subiterations.~.outputMode.OutputGeneratedSurface |
...
One of the result files cannot be written. This can happen while using parallelization (default). This can be resolved by adding following Advanced User Settings commands:
process.workers = 1 |
...
There are no privileges to access a file which is needed. Please check where the project folder is placed in which all the results are written. Network drives and cloud storage (e.g. OneDrive) are not recommended.
GPU Solving CUDA Solver Warnings & Errors
W5c7572a0
No operational GPU found for solving input (insufficient free memory).
Check the memory status of your GPU and terminate other programs that might affect the GPU memory.
W24850de8
Error Closing worker thread socket.
CUDA Solver is terminated although the optimisation is still running.
The optimisation will continue and fall back to local CPU solving.
Check the status of your CUDA Solver.
...
E3ee97ff0
supportReductionIntensity … is out of bounds 0-10.
Please adjust the Intensity value of the Support Reduction according to the boundaries.
E449a19a0
invalid supportReductionMode … expected off, passive, reactive or active.
Please set the Support Reduction Mode to one of the supported modes.
E4a364e88
missing / incompatible strutDensity setting for use with support avoidance.
If you are using the Support Reduction, you need to define a Strut Density.
W79aa1a40
fractured design space - make sure the model consists of only a single, connected body.