Name | Force/Moment/Pressure/Gravity | Direction (depending on local coordinate system) | Value in N/Nmm |
---|---|---|---|
Force - Moment 1 | Force on faces | z (Point of Application [25; 0 ;-12.5]) | -5000 |
...
Name | Force/Moment/Pressure/Gravity | Direction (depending on local coordinate system) | Value in N/Nmm |
---|---|---|---|
Force - Moment 2 | Force on faces | z (Point of Application [-100;0;-15]) | -2000 |
...
Force - Moment 3 is applied on the same surfaces like the first Force. This new Load is referring to the local coordinate system created earlier. It can either be selected from the viewport or the model browser using the selection tool or entering the coordinate system ID.
Name | Force/Moment/Pressure/Gravity | Direction (depending on local coordinate system) | Value in N/Nmm |
---|---|---|---|
Force - Moment 3 | Force on faces | x (local coordinate system 12; proposed center is point of application) | 7000 |
...
All boundary conditions must be assigned to the specific load cases, which are defined as Events. The number of Eventscan be changed by adding/deleting Eventsto the GD Scenario. The assignment of the boundary conditions to the Eventscan be made in the Loads & Constrains Window. The already created loads and constraints that concern the Design Space are listed in this window and can be activated for each Eventindividually.
Event 1: Force -Moment 1, Force -Moment 2, Constraint 1, Constraint 2, Constraint 3, Constraint 4, Constraint 5 and Constraint 6
Event 2: Force -Moment 2, Force -Moment 3, Constraint 1, Constraint 2, Constraint 3, Constraint 4, Constraint 5 and Constraint 6
...