Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

To set up these additional parameters, the Input Commands (left side of the table) need to be added to the optimisation model in the Advanced User Settings text field. In the picture below an example is shown. By adding these Advanced User Settings, the first (coarse) resolution level will be skipped and the optimisation starts directly at the second level. You might want to add more iterations to the remaining levels to give the optimisation the chance to reduce the material accordingly and reach a convergence in each level.

...

Restart (Start Space)

With the Advanced User Settings a Restart is possible. A Start Space needs to be chosen with which the optimisation will re/start.

...

A Start Space can be marked as a Non-Design Space, thus the Start Space cannot be removed during the optimisation and will be part of the final design. Therefore, the following command need to be added as well:

geometry.StartCandidate.path = StartCandidate.stl
nonDesign.StartCandidate.geometryName = StartCandidate