In this case one force is defined (on the top plate):

Name

Force/Moment/Pressure/Gravity

Direction

Value in N

Force - Moment 1

Force on cell

z

-1000

...

Three constraints for the three fixations are created and attached to the inner surfaces of the three cylinders:

Name

Direction

Constraint 1

x, y, z (=0)

Constraint 2

x, y, z (=0)

Constraint 3

x, y, z (=0)

...

Step 4: Interface Creation

...