In this case four forces and one moment are defined. The first two are applied on the retained volume and the last three on the faces of the interface that represents the connection to the sensor. Ensure to display the Design Space Solid to be able to apply Boundary Conditions.

Name

Force/Moment/Pressure/Gravity

Direction

Value in N; Nmm

Force - Moment 1

Force on Retained Volume

Fy; Fz

-1000; 1000

Force - Moment 2

Force on Retained Volume

Fx; Fy; Fz

600; -800; -200

Force - Moment 3

Force on Non-Design Space

Fy

-500

Force - Moment 4

Force on Non-Design Space

Fx; Fy; Fz

150; -200; -100

Force - Moment 5

Moment on Non-Design Space

Mz

-2000

...

Three constraints are created and attached on the Interfaces on the lower side:

Name

Direction

Constraint 1

x, y, z (=0)

Constraint 2

x, y, z (=0)

Constraint 3

x, y, z (=0)

...

Step 4: Definition of load cases

...

All result iterations are displayed as soon as they are available. Furthermore, you are able to stop the optimisation in this selection area. However, a Restart is not directly possible.

...

The whole MSC Apex Generative Design project with all results can be downloaded here:

View file
namePartConsolidation_2023-2.7z