Input Commands | Explanation |
---|---|
schedule.level.0.iterationCount = 19 schedule.level.1.iterationCount = 20 schedule.level.2.iterationCount = 20 schedule.level.3.iterationCount = 5 | Specify how many iterations are calculated at which resolution level. Note that convergence should be achieved at each level. Default settings medium: 19, 20, 20, 5 Default settings sparse: 15, 40, 4, 5 Default settings dense: 9, 10, 40, 5 |
schedule.level.0.eventSafetyCoefficient = 0.3 schedule.level.1.eventSafetyCoefficient = 0.4 schedule.level.2.eventSafetyCoefficient = 0.9 schedule.level.3.eventSafetyCoefficient = 1 | Scaling factor for all events' safety factor. Default settings medium: 0.3, 0.4, 0.9, 1 Default settings sparse: 0.6, 0.9, 0.95, 1 Default settings dense: 0.1, 0.25, 0.5, 1 |
geometry.startSpace.path=<restart-file.stl> | Specifies the Restar/Startspace file. |
The software uses four resolution levels from coarse to fine (level 0: coarse - level 3: fine). The number behind the level indicates the number of iterations calculated on this resolution level. To remove or skip a resolution level the value can be set to 0. Moreover, the Event Safety Coefficient for each resolution level can be changed. This coefficient is a scaling factor for the safety factor. More information about the safety factor, stress, failure criteria and resolution here.
To set up these additional parameters, the Input Commands (left side of the table) need to be added to the optimisation model in the Advanced User Settings Text Field. In the picture below an example is shown. By adding these Advanced User Settings, the first (coarse) resolution level will be skipped and the optimisation starts directly at the second level. You might want to add more iterations to the remaining levels to give the optimisation the chance to reduce the material accordingly and reach a convergence in each level. Especially level 2 can use more iterations in this case.
...
Restart (Start Space)
With the Advanced User Settings a Restart is possible. A Start Space needs to be chosen with which the optimisation will re/start.
...