Manufacturing Method: Generic AM
Failure Criteria: Von Mises
Stress Goal: 2 MPa
You can switch between the Safety Factor and Stress Goal in the properties panel by clicking the gear wheel.Select the Strut Density: Medium
Select the Shape Quality: Balanced
Set the Complexity Setting: 14
The Stress Goal seems to be chosen quite low for the material selection however when considering the low loading conditions, it is a suitable choice. The resulting stresses deliver a well-formed design.
...