Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Update Codes

In this section you find information about occurring warnings and errors. As we are continuously gathering information on how/when warnings and errors occur and under which circumstances this site will constantly be updated with new information.

...

Material is not valid. Condition 13 failed for orthotropic material

W6493a120

The configuration file entry 'solverMaxMemory' is deprecated, please use 'complexity' instead.

W1b158cd8

Unfeasible FEM setup: Insufficient fixed DOF.

Make sure that the model is appropriately fixated. A fixation needs to be applied in every global coordinate direction.

W1e44f6f0

Implausible FEM setup: No free DOF.

The whole Design Space is fixated so no material will be reduced.

W364cd738

Implausible FEM setup: Fixation space is poorly conditioned.

Make sure that the model is appropriately fixated. A fixation needs to be applied in every global coordinate direction.

W6d49ffc0

Unfeasible FEM setup: Missing fixation in one or more directions.

Make sure that the model is appropriately fixated. A fixation needs to be applied in every global coordinate direction.

W207f9b58

Smoothening of Isosurface data not available for …

Please contact MSC Apex Support.

W1535d930

Intermittent file system error …

The relocation of a file did not work. The simulation will continue.

W3080a2f0

Finalizing file << fn.u8string << failed

The relocation of several files did not work.

W39837ad0

Unused config entry …

The command is incorrect or was deprecated and will be not be considered in the optimization.

W7b364d00

Resolution … and complexity … specified together - ignoring complexity.

The resolution command is higher prioritised and outweighs the Complexity input.

W25081f18

Failure criterion Von Mises is not valid. The Tensile Strength is lower or equal zero for material …

Please change the material values according to the valid material conditions.

W0f25e2a0

Failure criterion Tsai Wu is not valid. One value is lower or equal zero for material …

Please change the material values according to the valid material conditions.

W7c709bf0

Failure criterion Tsai Wu is not valid. One value is lower or equal zero, or for Fxy, F_yz and F_zx not between -1 and 1 for material …

Please change the material values according to the valid material conditions.

W7b99b450

Failure criterion Tsai Hill is not valid. One value is lower or equal zero for material …

Please change the material values according to the valid material conditions.

W760ca740

Failure criterion Tsai Hill is not valid. One value is lower or equal zero for material …

Please change the material values according to the valid material conditions.

W658f5544

Adding autogenerated interface for boundary condition …

An Interface was not created for one or more boundary condition faces. For these faces an Interface was automatically generated to guarantee a satisfying result.

E7f716c48

This Error is only produced after another Error was encountered. The optimisation algorithm tried to continue despite the previous Error but could not continue. The optimisation fails with this Error although the primary Error is the reason for the terminated optimisation.

W6493a120

The configuration file entry 'solverMaxMemory' is deprecated, please use 'complexity' instead.

E4ebe0a20

Projected memory requirement exceeds available memory - complexity … (detail …) is too high. Theoretical limit: complexity … (detail …), recommended: complexity … (detail …)

...