Update Codes & Links

In this section you find information about occurring warnings and errors. As we are continuously gathering information on how/when warnings and errors occur and under which circumstances this site will constantly be updated with new information.

You can find Warning & Error codes displayed in the Studies tab by double clicking on the Generative Design Status or in the log files in the result folder in your workspace (log_error.log & log_warning.log).

...

Information regarding the “Analysis Readiness” checks can be found here.

W5754bb78

GPU solver was not requested, using CPU solver only.

...

This is an information regarding the usage of GPU solving. To use GPU Solving an additional license is necessary. Please check your licenses in Options → License Manager or deactivate GPU solving in the Options → Application Settings - Generative Design Solver.

...

Time estimation has become inconsistent, expect inaccuracies.

For Restarts and Two-Stage Optimisations the time estimation is inaccurat.

...

This might occur while performing a Command Line optimisation. The defined build space geometry is not defined as the design geometry. Therefore, the geometry needed for the intersection is not available and thus no intersection geometry is available. Please adjust the Configuration File.

W2f07aa98

Geometry … is not used by anything

This might occur while performing a Command Line optimisation. A geometry is not used in the optimisation. Please adjust the Configuration File.

W38a529d0

Failure criterion … is not used by anything

This might occur while performing a Command Line optimisation. The Failure Criterion is not used in the optimisation. Please adjust the Configuration File.

W6c825a00

Material is not valid. Condition 1 failed for Isotropic material …

W6c825a01

Material is not valid. Condition 2 failed for Isotropic material …

W6c825b00

Material is not valid. Condition 1 failed for transversal isotropic material …

W6c825b01

Material is not valid. Condition 2 failed for transversal isotropic material …

W6c825b02

Material is not valid. Condition 3 failed for transversal isotropic material …

W6c825b03

Material is not valid. Condition 4 failed for transversal isotropic material …

W6c825b05

Material is not valid. Condition 6 failed for transversal isotropic material …

W6c825b04

Material is not valid. Condition 5 failed for transversal isotropic material …

W6c825b06

Material is not valid. Condition 7 failed for transversal isotropic material …

W6c825c00

Material is not valid. Condition 1 failed for orthotropic material …

...

W6c825c02

Material is not valid. Condition 3 failed for orthotropic material …

W6c825c03

Material is not valid. Condition 4 failed for orthotropic material …

W6c825c04

Material is not valid. Condition 5 failed for orthotropic material …

W6c825c05

Material is not valid. Condition 6 failed for orthotropic material …

W6c825c06

Material is not valid. Condition 7 failed for orthotropic material …

W6c825c07

Material is not valid. Condition 8 failed for orthotropic material …

W6c825c08

Material is not valid. Condition 9 failed for orthotropic material …

W6c825c09

Material is not valid. Condition 10 failed for orthotropic material …

W6c825c10

Material is not valid. Condition 11 failed for orthotropic material …

W6c825c11

Material is not valid. Condition 12 failed for orthotropic material …

W6c825c12

Material is not valid. Condition 13 failed for orthotropic material …

...

A Non-Design Space was removed and the applied boundary conditions are not considered

The Design Space has lost the connection to the force/constraint application point. The model is no longer complete and it doesn’t make sense to continue with the optimisation.

Make sure that the Keep Non Design function is activated. Increase the Complexity or increase the Safety Factor.

Eb20f3980

Missing config entry …

The configuration file is missing an entry or command. Please check your entries in the Advanced User Settings or if you are using the Command Line Optimisation please check the Configuration File. You can find all commands for the Advanced User Settings here and the Configuration File here.

E0d03bf38

Unable to resolve input file name statistics.csv

This may occur if an optimisation is started with Advanced User Settings with which only 1 or 2 iterations should be calculated. If this is the case please add the following Advanced User Settings commands:

schedule.level.3.subiterations.~.outputMode.OutputGeneratedSurface

E39d2c328

unexpected error loading file statistics.csv: Unable to open input file

This may occur if an optimisation is started with Advanced User Settings with which only 1 or 2 iterations should be calculated. How to resolve this here.

schedule.level.3.subiterations.~.outputMode.OutputGeneratedSurface

E58799450

unexpected error writing file file_name.ply:

One of the result files cannot be written. This can happen while using parallelization (default). This can be resolved by adding following Advanced User Settings commands:

process.workers = 1

GPU Solving CUDA Solver Warnings & Errors

...

Check the memory status of your GPU and terminate other programs that might affect the GPU memory.

W24850de8

Error Closing worker thread socket.

...