In this case four forces and one moment are defined. The first two are applied on the retained volume and the last three on the Non-Design Space that is connected to the sensor:. Ensure to display the Design Space Solid to be able to apply Boundary Conditions.
Name | Force/Moment/Pressure/Gravity | Direction | Value in N; Nmm |
---|---|---|---|
Force - Moment 1 | Force on Retained Volume | Fy; Fz | -1000; 1000 |
Force - Moment 2 | Force on Retained Volume | Fx; Fy; Fz | 600; -800; -200 |
Force - Moment 3 | Force on Non-Design Space | Fy | -500 |
Force - Moment 4 | Force on Non-Design Space | Fx; Fy; Fz | 150; -200; -100 |
Force - Moment 5 | Moment on Non-Design Space | Mz | -2000 |
...