With the Advanced User Settings the optimisation parameters can be influenced even further than the options Strut Density and Shape Quality. Furthermore, a few unsupported options are available using the Advanced User Settings like Restart, Usage of a Startspaceand preventing an Intersectionduring the optimisation.
The Advanced User Settings can be added to a Scenario by right clicking on this and selecting the option as shown in the picture below.
...
Restart, Usage of a Start Space & Influencing the Strut Density
To influence the Strut Density even further, changes of the number of iterations, stress goal percentage and number of resolution levels can be made. These settings overwrite the selection of the Strut Densityand the Shape Quality as they are only default settings for the ones described here. The table gives an overview of the default settings:
...
The software uses four resolution levels from coarse to fine (level 3: coarse - level 0: fine). More or less resolution levels can be added or removed. The number behind the level indicates the number of iterations calculated on this resolution level. Moreover, the stressPercentGoal for each resolution level can be changed. More information about the stresses and resolution here.
To set up these additional parameters, the Input Commands (left side of the table) need to be added to the optimisation model in the Advanced User Settings Text Field. In the picture below an example is shown. By adding these Advanced User Settings, the first (coarse) resolution level will be skipped and the optimisation starts directly at the second level. You might want to add more iterations to the remaining levels to give the optimisation the chance to reduce the material accordingly and reach a convergence in each level. Especially level 2 can use more iterations in this case.
...
Therefore, an already optimised STL-file is needed as a Start Space. This can be exported directly from the post processing and be selected as a Start Space by clicking on the browse button. Therefore, the unit of the exported STL-file needs to be in meters (SI-Units). In most cases the Strut Density and Shape Quality settings must be changed as well using the Advanced User Settings. For a restart the same resolution level and number of to be completed iterations have to be filled in. You can find a Tutorial to how to perform a Restart here.
...
Per default all Non-Design surfaces grow a little bit beyond their boundaries to ensure a trouble-free and clean intersection. This is done with an automatic detection of Non-Design faces. Sometimes this can lead to issues.
Every time when Machining Allowances are applied on all functional surfaces this function can be deactivated. Even if this surface won’t be post processed and no additional material is needed, a Machining Allowance of 0 mm can be applied. This ensures sharp edges and planar, functional surfaces after the intersection.
How the automatic Non-Design growth influence the resulting geometry here.
This automatic growing can be deactivated with the Advanced User Settings command below:
...