In this section you find information about occurring warnings and errors. As we are still gathering information on how/when warnings and errors occur and under which circumstances this site will constantly be updated with new information.

You can find Warning & Error codes displayed in the Studies tab by double clicking on the Meshless Generative Design Status or in the log files in the result folder in your workspace (log_error.log & log_warning.log).Link

Information regarding the “Analysis Readiness” checks can be found here. Link

Please contact the MSC Apex Support (mscapex.support@mscsoftware.com) if a warning or error occurs which is not yet listed here or cannot be averted by applying the compiled help.

...

This is just a notification that the predicted reduction of the model is very high.

Further information here.

Wf9b42fd9

“Probable reduction of the model is more than …% of the starting model.”

...

If further problems occur, please contact MSC Apex Support.

W1cab408b

The software versions of the engine and the solver do not fit together.

Interne Meldung, für Apex und uns vor einer Release

No connection to the extern solver was possible. The optimization will continue and fall back to local CPU solving.

Please contact MSC Apex Support.

W39fed060

The Matrix is too large for the GPU solver.

...

If you have used the GUI to setup the model, this will be handled automatically.

W7aa7a778

Machining offset " << ident << " is too small to be represented

W74bbc128

Machining offset is much larger than design space. Please check unit dimensions in configuration

W2ab3f0d8

Machining offset protrudes build area box

W61379840

Meshfix warning …

...

Please contact MSC Apex Generative Design support for further help.

W94d7c884

Restart file volume is magnitudes smaller than design space. You might want to check restart file scaling

W1cb255fc

Unable to find file for optimisation space … .

...

Please contact MSC Apex Generative Design Support.

W2ae386d0 - überhaupt beim Kunden?

invalid reconnectionStrategy setting: Expected Default, AllShortestPaths or GreedyShortestPaths

W42f987d5

Restart file found: …

Restarting at iteration …

Restart file found: " << this->restartFile << " - Restarting at iteration "<< this->restartIteration

The optimisation run was interrupted/restarted . The run will continue with iteration … as a starting point.

W1c88afc8

No defined value for the complexity was found in the configuration file.

...

For further questions please contact MSC Apex Support.

We8844d64

Remesh failed

W1cbb4449

There is not enough memory (RAM) available for the optimisation to continue.

...