In this Tutorial is shown how to perform a Restart. Therefore the Advanced User Settings are needed. More information to a Restart here.

Instead of the Design space another volume geometry can be chosen as the Start space. The Design space is still the limit for this optimization. With this option a terminated optimization can be continued or a two-stage optimization with varified optimization parameters can be done.

...

For a Restart a new scenario should be created. With the Advanced User Settings the Start space STL-file can be selected. In this case the exported iteration 22 from an former optimization. Furthermore the symmetry constraints from the first optimization are added.

...

A seconed possibility is to perform a two-stage optimization. Instead of a simple restart with the same optimization parameters the parameters can be verifiedvaried.

Examples:

  • Skipping the coarse resolution level and caluclate directley on the finest resolution level with an early iteration from a former optimization, if a very fine high-resoltion level is desired

  • Varify Vary the value for the stress goal to keep the overall geometry with more or less material

  • Modify an optimization output (remove or add struts) and restart with this modified geometry

  • Creation of a lattice stucuture of an optimization output and restart to optimize the lattice

...