The stress calculation is from an FE point of view an estimation. That’s why we recommend a FE reanalysis using Apex Structures/Nastran to verify the results regarding all boundary conditions. For the reanlysis the intersected model should be used which will be manufactured. The reanalysis can also take dynamic loading & other boundary conditions into consideration. For more information regarding intersection have a look here.